Technical characteristics of the drying plant ACM-2000 |
Drying plant size (length x width x height) |
mm |
7100x1900x2700 |
Number of chambers and carrier |
kom |
5 |
Weight of the empty drying plant |
kg |
1400 |
Size of the tray (shelf) |
mm |
800×1600 |
Number of shelves by carriers and the total number of shelves |
kom |
21(105) |
Quantity of the products per shelf (based on plum) |
kg |
20 |
Capacity of the drying plant based on plum |
kg |
2100 |
Maximum flow of one ventilator |
m3/h |
8000 |
Installed heating capacity |
kW |
70 |
Installed power capacity |
kW |
28,4 |
Maximum electrical consumption per 1 kg of prunes with pits (24h) |
kWh |
1,36 |
Losses of heat conduction through a sheath (24 h) |
kWh |
21,4 |
Maximum water temperature in the system |
℃ |
75 |
Maximum air temperature in the drying plant |
℃ |
65 |
Hook up cable |
Cu |
5x16mm2 |
Power supply |
|
3×380 V,50Hz, AC |
Main fuses |
A |
63 |
COP of heat pump air to water (A20/W65) |
|
3,10 |
COP drying plants |
|
2,95 |
Max. moisture extraction rate – MER |
kg/h |
200 |
SMER specific moisture extracted ratio in respect to input energy |
kg/kWh |
2,93 |